| Input |
|
| Input Voltage |
Universal 85-264VAC, 47-63Hz |
| Input Current |
3.3A rms max. |
| Input Protection |
Inrush current limiting |
| Thermal Fuse |
Internal |
| Input Isolation |
2250 VDC input to chassis 4300 VDC input to output, 8mm spacing 500 VDC output to
chassis |
| RFI Suppression |
Meets requirements for EN 55022 Class A Conducted emissions as a minimum |
Output |
|
| Output Voltage/Current |
+21VDC @ 4Amp, -21VDC @ 3Amp |
| Line Regulation |
.0.5% |
| Load Regulation |
+/- 5% from 10% load to full load for bothoutputs with redundancy diodes |
| Temperature Drift |
0.03% per degree C over operating temp. range |
| Operating Temperature Range |
0 - +50 degree C for full specifications with natural convection cooling |
| Output Ripple Voltage |
Better than 40mVrms or 200mVpp (20Mhz BW)for both outputs, 60Hz ripple is
30mVrms max. |
| Output Protection |
Rectangular current limiting with hiccup mode short circuit protection. Thermal
shutdown with automatic reset in case of continuous overload |
| Output Overvoltage Protection |
Transzorbs installed on each output |
| Efficiency |
Minimum 80% at full load |
General |
|
| Package Size |
Open frame unit 10.5" L x 2.6"W x componentheight 1.5" above PCB |
| Heatsink Plate |
9.459"L x 2.575"W |